2/9/04 Professor to student: Before you leave town [please write] a Word writeup about the lab accident. The focus is on
(1) getting as many details as possible,
(2) describe the "root" cause(s) even if you regret doing something.....This is not to embarrass or punish anyone, including me. She wants you to be as blunt and complete as possible even if it includes admitting mistakes. Include the date, time, materials involved, quantities, and chronology of events. Name the people who helped out-rang the alarm, used extinguishers,
Student report: On Thursday, Feb.5th at approximately 4:00 P.M. I was performing a recrystallization. The process involved warming some acetone (<5ml) in an Erlenmeyer flask on a hot plate. After checking as to whether the acetone was warm to touch I added some pet. ether to the flask. All of a sudden I saw and heard the Erlenmeyer flask blow with smoke, but I don't recall seeing any fire until the 4 liter bottle of pet. ether in my hood and my hood floor became inflamed. The pet. ether bottle was sitting in the corner of my hood near the vacuum line.
There were several other organic preps in my hood that were sitting in chloroform and dichloromethane solvents. At the time I thought there was a great possibility that my hood would explode due to all of the organic solvents so I move the 4 liter bottle of flaming pet. ether to the sink and called for a fire extinguisher. The first extinguisher (Alex Shelton) didn't help nor did the second fire extinguisher (Mike Wilson). The fire become more aggressive and the sprinkler system activated. In the process of trying to put out the fire the undergraduate (Becky) in the lab ran to pull the fire alarm. We could not contain the fire so as we were getting ready to evacuate the immediate lab Dr. Rothwell entered the lab and told tell us to leave the building. So we closed the door to the lab and left the building.
What went wrong, what has been learned....
1 -- A hood is NEVER to contain ANY unnecessary flammable liquids or items that would burn easily if any of the work taking place in it is capable of causing a fire.
2 -- The first thing you do is call 911 or pull the fire alarm if it's closer than the phone.
3 -- Never take a burning object out of a hood. Close the hood, call 911, leave the room.
This fire came way to close to getting out of control. We were very lucky.
There are a number of academic departments and entire institutions which have decided against having fire extinguishers in the labs, because of this kind of mistake can take lives and burn down whole buildings.
In our own Electrical and Computer Engineering Department, for example, nobody except firefighters and three annually trained professional staff members are allowed to use the extinguishers. Graduate students or postdocs who break this rule are given a "time out" (kicked out of the lab) for a couple of weeks.
Trying to put out a fire is not inherently wrong, but the procedure in this case -- taking the container out of the hood and failing to call 911 immediately -- showed a horrible failure of training.